Main Configuration: 3.5MHzR50 Convex Array Broadband Probe (Frequency Range: 2.0MHz~5.5MHz)
Performance Indicator | Performance Requirements | (at various frequencies from 2.0MHz to 5.5MHz) |
---|---|---|
Probe Frequency (MHz) | 3.5 (nominal) and various frequencies from 2.0MHz to 5.5MHz (variable) | |
Operating Frequency (MHz) | The deviation of the operating frequency from the nominal frequency should be within ±15%. Nominal frequency: 3.5MHz | |
Depth of Penetration (mm) | ≥180 at 3.5MHz, ≥190 at 2.0MHz and 3.0MHz, ≥160 at 4.0MHz and 5.0MHz, ≥140 at 5.5MHz | |
Lateral Resolution (mm) | ≤3 (depth ≤80), ≤4 (80<depth ≤130) at frequencies below 4.0MHz; ≤2 (depth ≤60) at frequencies of 4.0MHz and 5.5MHz | |
Axial Resolution (mm) | ≤2 (depth ≤130) at frequencies below 4.0MHz; ≤1 (depth ≤80) at frequencies of 4.0MHz and 5.5MHz | |
Blind Zone (mm) | ≤4 | |
Lateral Geometric Position Accuracy (%) | ≤5 | |
Longitudinal Geometric Position Accuracy (%) | ≤5 | |
Slice Thickness (mm) | ≤6 | |
Perimeter and Area Measurement Deviation (%) | ≤8 | |
M-Mode Time Display Error (%) | ≤5 |
(The performance requirements for the optional probes, namely 3.5MHzR20, 6.5MHzR10, and 7.5MHzL40, are similarly detailed but with specific ranges and values tailored to their respective configurations and frequency ranges.)
Color Flow Imaging Mode Performance Requirements
In the color flow imaging mode, the detection depth of each probe at its Doppler operating frequency should meet the following requirements:
(Detailed table specifying Doppler frequencies and detection depths for each probe model.)
Color flow images should basically coincide with the grayscale images of the vessels they are within. Blood flow direction should be correctly identified without aliasing.
Spectral Doppler Mode Performance Requirements
In the spectral Doppler mode, the detection depth of each probe at its Doppler operating frequency should also meet specific requirements.
(Detailed table specifying Doppler frequencies and detection depths for each probe model, similar to the color flow imaging mode.)
The blood flow velocity reading error of the color Doppler ultrasound should not exceed 20%. The cursor position in the sampling area should be accurate.
1.3.4 Various Functions
Display Modes:
Color Flow Image Adjustment Parameters:
(Tip on interpreting color flow information based on color brightness and direction relative to the probe.)
Probe Types:
Sound Power:
Display Depth:
Focusing:
B-mode Display:
M-mode Display:
Digital Beamforming:
Signal Processing and Doppler:
Image Processing Functions: