FTL-FM1 ctg machine 12.1 Inches Monitor Fetal Doppler Electronic Fetal Heart Monitoring Wireless Fetal Monitor Fetal Baby Monitor FTL-FM1
$900.00~1700.00 / Parcel$1700.00 Min.order:1
Super Low Price
Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products 12.1 inch Folded high-brightness TFT LED(Optional touch screen) 12-Crystal ultrasound transducer achieves a wider focal region for more uniform coverage at greater depths than conventional 9-crystal Built-in high-speed thermal printer, printing width can be set to 112mm, 150mm

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

FTL-FM1 ctg machine 12.1 Inches  Monitor Fetal Doppler Electronic Fetal Heart  Monitoring Wireless Fetal Monitor Fetal Baby Monitor

Performance Specifications
Dimension360mm*310mm*120mm
Weight5.3kg(excluding accessories)
Power SupplyVoltage AC100~240V, 50/60HZ
Display12.1" color TFT LED (0-90° rotation) Resolution 1024*768 pixels
Battery (Built-in)Type Rechargeable lithium battery 14.8V/2200mAh
Charge Cycle≥500 times
Working time2 hours
Recorder (Built-in)
MethodThermal printer
PaperZ-fold, thermosensitive
Paper width112 mm (4.41 in)/150 mm (5.91 in)
Printing speed1/2/3cm/min
TraceMax. 4 tracks
-Recording wayReal-time Recording, Review Printing
Alarm
LevelLow, medium and high
IndicationAuditory, Visual, Delay of FHR Alarm
Input Device
-Touch screen (option)
-Knob (Standard)
-Keypad input (Standard)
Mouse/Keyboard input (option)
-USB port for patient data/NST report backup (option)
System Output & Extensible Interface
-Ethernet Network1 standard RJ45 socket
-USB Port2
-Video Output1 HDMI port (option)
Trend & Reviewing
-Cardiotocography (CTG)
Waveform Review8640 hours
-Vital Signs
Trend2160 hours
Waveform Review2 hours
NIBP Review2000 groups
-Alarm Review2000 groups
Safety
-IEC60601-1 Approved, CE marking according to MDD93/42/EEC
-With reference to RoHS Directive 2011/65/EU recasting
-Ultrasound (FHR)
-Transducer type12-Crystal ultrasound transducer
-Measure methodWide beam pulse doppler
-FHR Measurement range
30 to 240 bpm (US Standard)
50 to 210 bpm (Europe Standard)
Accuracy±1 bpm
Intensity<3 mW/cm2
-Ultrasound frequency1MHz±3%
Resolution1 bpm
TOCO
-Measurement methodStrain gauge sensor element
-Measure range0 ~ 100 units
Resolution1 unit
-Nonlinear deviation≤±8%
-Baseline setting0,5,10,15, 20 can be selected
-Auto offset correction3 second after connecting the transducer
-Auto zero adjustTOCO value is set to zero negative following a negative Measure value for 5 seconds
Fetal Movement Recording
-Automatic fetal movement (AFM)pulsed doppler ultrasound
-Automatic fetal movement autograph
-Manual fetal movement marker (MFM)
Maternal ECG
-Lead mode3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
A63Gain2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, Auto
Sweep speed6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s
Accuracy±1bpm/ ±1%, whichever is greater
Resolution1 bpm
Leakage Current < 10 μA
CMRRDiagnostic Mode >89 dB

Monitor Mode >105 dB

Surgery Mode >105 dB
BandwidthSurgery 1 ~ 25 Hz

Monitor 0.5 ~ 40 Hz

Diagnostic 0.05 ~ 120 Hz
Maternal Heart Rate
-Measure rangeAdult:0bpm; 10 ~ 300 bpm

Neonate:0bpm; 10 ~ 350 bpm
Resolution1 bpm
Accuracy± 1% or ± 1bpm, whichever is greater
ST Measurement
Range-2.0 ~ +2.0 mV
Accuracy-0.8mV~+0.8mV:±0.02mV or ±10%, whichever is greater
-Other rangeunspecified
Resolution0.01mV
Maternal Respiration
MethodImpedance between RA-LL, RA-LA
Gain×0.25, ×0.50, ×1, ×2, ×4
-Respiration Rate0bpm, 6 ~ 150 bpm
Resolution1 bpm
Accuracy±2 bpm or ±2%, whichever is greater
-Apnea Alarm10 ~ 60 s
Maternal SpO2 (Digital Technic)
-Measurement Range0 ~ 100 %
Resolution1%
Accuracy±2% (70% ~ 100%)
±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
Pulse Rate
Range25~250bpm
Accuracy±1% or ±1 bpm, whichever is greater
Resolution1bpm
Maternal NIBP (MNIBP)
MethodOscillometric
-Measure mode Manual, Auto, STAT
-Measure Interval in AUTO Mode 1~480 min
-STAT mode cycle time
-Keep 5 minutes, at 5 seconds interval
-Measure and Alarm Range
Systolic30~270 mmHg
Diastolic10~220 mmHg
Mean20~235 mmHg
-Static pressure accuracy ±3mmHg
Resolution1mmHg
AccuracyMaximum Mean error ±5mmHg
Maximum Standard deviation 8mmHg
-Over pressure ProtectionDual protection via software & hardware
Maternal Temperature
TechniqueThermistor probe (2.25K)
-Measuring and Alarm Range0.0 ℃~ 50 ℃ (32℉~ 122℉)
UnitCelsius (℃), Fahrenheit ( ℉)
Resolution0.1℃
Accuracy±0.1℃
NST Report/FHR Interpretation (Option)
-Based on Fischer Evaluation Method (monitoring time≥20 Min)
-Average Baseline FHR /Number of Acceleration /Number of Deceleration /Number of Small Acceleration /Amplitude Variation /Number
of PV
-Automatic Score ResultScore 8-10 (Excellent)
Score5-7 (Suspicious)
Score ≤4 ( Fetus Hypoxia)


Model NumberFTL-FM1
Power SourceElectricity
Materialmetal, Plastic, Steel
Shelf Life1years
Product nameFetal Monitor
Display12.1 Inch LED
BatteryRechargeable lithium battery 14.8V/2200mAh
FunctionMedical Examination
purposeExamination department
Resolution1024*768 pixels

The specific parameters should be based on what the sales representative provides