Japan Toray Dialysiser system Single Patient Dialysis Machine TQS-88 kidney dialysis machine prices Hollow-fiber Dialysis Machine Mobile dialysis machine
$1000.00 / Parcel$100000.00 Min.order:1
Brand Sales
The single patients dialysis machine can perform prescribed dialysis which adjust the dialysate conductivity in accordance with each patient. It mainly consists of Monitor/alarm part, Dialysate supply/UF control part, Extracorporeal blood circuit part, and Electrical control part.

Support Payment Term:

HSBC Hong Kong

paypal

Alibaba Pay

Western Union

USD

EUR

GBP

SGD

HKD

CNH

CAD

MXN

BRL

JPY

THB

MOP

AUD

NZD

PLN

CZK

HUF

RON

CHF

SEK

NOK

DKK

TRY

AED

SAR

ILS

ZAR

$0.00

Quantity

Discover similar items

Page 1 of 2

Features

Supported by the advanced technologies of Toray, Type:TQS-88 offers comfortable dialysis treatment to patients and easy operation to medical staff.

  1. Humanized design & Convinient operation
    10.4 inch LCD touch panel, Drip chamber level adjustment, etc.
  2. Optional functions for comfortable dialysis treatment
    Bicarbonate cartridge holder, On Line HDF, Kt/V Indication, BVM(Blood Volume Monitor), etc.
  3. Effective maintenance assistant
  4. Safety and reliability of treatment based on advanced technology

    Specifications

    Power supply:220-230V,50/60Hz
    Max.power consumption:1.5 kVA
    Dimensions (W X H X D):322 X 1,378, X 375 mm main body only
    Weight:max. 85 Kg
    Pressure of supplied water:0.1 to 0.3 Mpa
    Flow rate of supplied water:800mL/min or greater
    Temperature of supplied water:5 to 30 ℃
    Quality of supplied water:equivalent to or better than ISO23500 Guidance
    Range of dialysate temperature regulation:33 to 40 ℃
    Range of dialysate flow rate regulation:300 to 700 mL/min
    Range of UF rate regulation:0.00 to 5.00 L/h
    Range of dialysate conductivity regulation:
     Acetate dialysis and bicarbonate dialysate13.0 to 16.0 mS/cm in 1-9 steps (in increments of 0.3mS/cm)
    Substitution pump rate setting range:0.0-18.0 L/h (On-line HDF option)
    Substitution goal amount setting range:0.01 - 99.99L (On-line HDF option)
    Range of blood flow rate regulation:
     Inner Diameter 8.0mm0, 30 to 600 mL/min
     Inner Diameter 6.5mm0, 20 to 400 mL/min
    Range of syringe flow regulation:0.0 to 9.9 mL/h (with rapid function)
    Available syringe size:10 mL / 20 mL / 30 mL
    Air bubble detector:ultrasonic detection system
     Sensitivity:Greater than 0.020 mL
    Greater than 0.3 μL (Continuous air bubbles)
    Blood leak detector:Photoelectric detection system
     Sensitivity:Greater than 300 ppm (Ht.32%±2%, 37℃ condition)
    Disinfection:Hot water disinfection or chemilcals