Pulsating Vacuum Sterilizer HTYM-23L
Support Payment Term:
$0.00
Discover similar items
Page 1 of 2
model | name | Technical parameter description |
1 | product model | HTYM-23 |
2 | product form | table model |
3 | heating method | electrical heating |
4 | vapour system | Built-in electric steam generator |
5 | power | 2.9KVA |
6 | source | AC220V,50Hz |
7 | outline dimension | 700*530*425mm |
8 | inner liner size | Φ250mm * 450mm |
9 | available capacity | 23L |
10 | energy consumption | Approximately 1.5 KWh per batch |
11 | tank capacity | 1.5L |
12 | upwelling | It comes with a self-priming pump and can connect to a pipeline for automatic water supply. |
13 | water consumption | 0.6L |
14 | displacement | 0.6L (all except a small amount remaining on sterilized articles) |
15 | Materials used for the sterilization chamber | The sterilization chamber is made of 304 corrosion-resistant stainless steel. |
16 | work environment | 0℃~40℃ |
17 | working pressure | 105KPa/121℃ (at standard atmospheric pressure) and 210KPa/134℃ (at standard atmospheric pressure) |
18 | Humidity during sterilization | ≥80% |
19 | Temperature/sterilization time (recommended) | 121℃/20 minutes 134℃/5 minutes |
20 | display screen | 4.3-inch LCD with resolution ≥480*272 |
21 | USB joggle | Supports USB export of sterilization records |
22 | nominal working pressure | 0.22MPa |
23 | maximum working pressure | 0.25MPa |
24 | Applicable items | Surgical instruments, dental handpieces, dressings, glassware, cavity instruments, heat-resistant plastics and other items that can withstand 121℃ or 134℃ sterilization were sterilized. |
25 | pulsating vacuum method | Perform pre-vacuum pulsation three or more times to efficiently expel cold air and ensure steam penetration |
26 | Drying function | Thermal vacuum drying or pulsating negative pressure drying, with low residual moisture and drying time adjustable between 600 to 2000 seconds. |
27 | control method | PLC automatic control, LCD screen with touch buttons |
28 | security guard | Overheat protection, overpressure protection, low water level/anti-dry burn protection, safety door lock (door cannot be opened if pressure is not released), automatic pressure relief valve |
29 | relief valve | When the pressure in the sterilization chamber exceeds 0.25MPa, the safety valve automatically releases the excessive pressure, ensuring reliable performance. |
30 | printer | Using a micro printer, the data of each minute during the whole process of sterilization can be printed and permanently stored. |
31 | endogenous vaporization | Built-in condensate collector. Waste steam is condensed and discharged by the condenser. |
32 | alarm system | The equipment is equipped with an automatic detection and alarm system. |
33 | test function | Support Bowie & Dick (BD) testing and vacuum leak testing |
34 | Category | Class II medical devices |