direct digital X-ray photography system DX-8000A
About this item:
Support Payment Term:
PayPal
USD
EUR
GBP
SGD
CNY
MXN
BRL
JPY
THB
AUD
$168888.00
Discover similar items
Page 1 of 2
l DX - 8000 - a chassis suspension parameters suspension support structure l
l electric multi-function photography system stand (100 cm, 180 cm)/decubitus conversion l
l projection position: Stand 1000 mm / 1800 mm, recumbent position and oblique l
l X bulb lateral movement range: mobile travel l
l X 1800 mm + 50 mm ball tube longitudinal motion range: mobile travel l
l X 1800 mm + 50 mm ball tube vertical movement range: Mobile travel l
l X 1500 mm + 50 mm ball tube rotation range: rotation Angle 0 ° plus or minus 2 ° ~ + 90 ° plus or minus 2 ° l does the sternum craft bracket vertically range: 500 mm to 1700 mm + / - 5% l
l chest radiograph craft bracket rotation Angle range: 0 ° plus or minus 2 ° ~ 90 ° + 2 ° l
l made a film from the SID: 1000 mm to 1800 mm
l lie a film from SID: 1000 mm l l l
l bed structure mobile photography
l bed
l bed surface: long x 2200 mm x 800 mm wide l
l height: 670 mm
l material: carbon cellulosic polymer high voltage generator
High voltage generator
l Power: 50 kw
l KV photography: 40 KV ~ 150 KV
l Photography mA: 10 ~ 640 mA
l MAs: 0.1 mAs ~ 500 mAs
l Inverter frequency: ≥40kHz
l ARP: support
l Control mode: console operation
X-ray tube assembly
l Focus size: 0.6/1.2
l Focus power: 20kW/50kW-50HZ
l Anode heat capacity: 300kHU
l Heat capacity of tube sleeve: 1250kHU
l Anode target Angle: 12°
l Maximum tube voltage: 150kV
★Direct Digital Imaging Detector (import)
Material: amorphous silicon cesium iodide implant
l Size: 14 x 17 inches
l Pixels: 7 megapixels
l A/D: 16 bits
l DQE: 70%
l Pixel matrix: 2448×2984
l Pixel size: 143 m
l Imaging time: ≤3s
l Ultimate resolution: ≥3.7LP/MM
l Data transmission mode: mobile wire
Limit beam splitter
l Specification: AC24V / 100 w
l Control mode: manual
l Minimum exposure field: <50mm×50mm
l Radiation field (SID=1000mm) :430mm×430mm
l Average exposure brightness: >140Lux;
l Illumination: >4:1
l Intrinsic filtration: 1.0mmAL equivalent
l Lead equivalent of shield blade: 3mMPB (intermediate blade: 2mMPB)
The filter wire grid
l Grid density: ≥80L/cm
l Grid ratio: ≥ 10:1
l Grid focal length: 100cm/180cm
The workstation
l CPU: Kujong I5 quad-core 3.2ghz
l Memory: 4 gb
l Hard disk capacity: 1TB
l DVD drive: DVD drive
l System interface: USB, RS232, DVI/VGA/HDMI/DP, COM serial port, PCI/PCI-E
l Monitor: 22 "LCD
l Operating system: Windows 7 Pro legal edition
Workstation software functions
l User operation: patient information registration, multi-condition inquiry of location patient information, patient appointment, emergency treatment,
l Image processing functions: window width/window, local automatic window width/window bits, preset width/window, plus or minus as inversion, image rollovers, rotating, image magnification and roaming edge enhancement, image interpolation, local amplification, restore the original image, text/digital annotation, image scale line measurement, Angle measurement, brightness/contrast adjustment
l Image printing: DICOM printing, paper printing, image contrast/brightness adjustment, multi-image piecing printing, film size selection, print queue control.